Filter Fans
Forced ventilation fans maintain the correct temperature inside the cabinet by exchanging heated inside air for cool outside air.
Forced ventilation fans maintain the correct temperature inside the cabinet by exchanging heated inside air for cool outside air.
MAIN ADVANTAGES:
- Mount without screws into square openings using elastic clips
- Replace the filter membrane from the outside without tools
- Reversible airflow direction
- Airflow up to 800 m³/h
- Installation for plate thickness between 1,5 mm and 2,5
- IP 54 standard rating
- Wall and top mounting options
- Operational temperature range from -10 °C to +70 °C
- Permanent sealing gasket in polyurethane foam
- UV protection
Parametr | Value |
---|---|
Material | PC/ABS Alloy, PA 66 GH13 HSL for elastic clips |
Color | RAL 7035 (other on request) |
Filter media |
Thermo-linked progressive structure with synthetic fiber G3, according to EN 779 Can be washed up to about 10 times |
Dust retention capacity |
600 g/m2 |
Protection degree |
IP54 (IP55 using special filter mats, IP56 using hose-proof cover) |
Airflow direction |
Reversible |
Sizing |
When we use fan filters, we must have a target temperature inside the cabinet that is greater than the ambient temperature outside the cabinet (Te), which makes the difference (ΔT) between the inside and outside temperatures always positive. We can calculate the fan filtered airflow by taking the ratio between the thermal power (Q ) and the temperature difference (ΔT) and multiply that by the heat transfer coefficient (f ), which considers the physical properties of air, including heat and density which can change with altitude (m). |
Fixing system |
By elastic clips, otherwise by four self-threading screws |
Supply includes |
Unit with filter mat ready for connection |
Recommendations for installation |
The filter fan unit should be placed in the lower part of the enclosure to allow the cool air to enter into the enclosure and form a slight overpressure. This means that air flows into the enclosure through the filter fan unit without any dirt/dust and removes warm air from the enclosure through the outlet filter grid. If the filter fan unit is installed in the opposite direction, dust and dirt can enter into the enclosure along with cool air. The filter fan unit should be placed in the bottom third of the cabinet and the outlet filter grid should be placed as high as possible. This will prevent the accumulation of warm air in the upper part of the enclosure. |
Filterfanunit_3.jpg
File size: 63 kB
Air_flow_Filterfan_unit.jpg
File size: 40 kB
Filterfanunit.jpg
File size: 48 kB
Filterfanunit7.jpg
File size: 150 kB
Filterfanunit6.jpg
File size: 108 kB
Filterfanunit_2.jpg
File size: 121 kB
Filterfanunit5.jpg
File size: 66 kB
Filterfanunit_4.jpg
File size: 62 kB
Catalog
Product Catalog—Data and Telecommunication Solutions and Racks
File size: 24466 kB
Brochure—Complete Solutions for Datacenters
File size: 3003 kB
Brochure—Cooling Units For IT
File size: 3733 kB
Brochure—Solutions for Server Rooms and Cabling Installations
File size: 1210 kB