Implementation of a micro data center in the heart of Andalusia
A modern company praised our solution based on RF1 rack cabinets.
Small CoolSpot and CoolSeven air conditioning units are designed for low and medium heat loads and represent a group of precision cooling units within the PREMIUM and OPTIMAL series.
We offer two different types of units: with water cooling (CW) for connection to the cold water system in the building, and with direct evaporation (DX). CoolSeven cooling units are particularly cost- and power-efficient.
Cooling unit parameters | CoolSeven with CoolOut | CoolSpot |
---|---|---|
Cooling performance | DX: 0.8 kW - 7 kW |
DX: from 0.32 kW to 5.2 kW CW: from 2.2 kW to 6.7 kW |
Minimum cooling capacity |
✔ From 11% (Hot Gas Bypass: lower cycling tendency) ✔ EC fans (controlled from 20% of max. speed) ✔ Separation of cold and hot zone by separation frame and plugs |
from 30% (frequent short compressor cycles) Standard AC fans (without speed control) Cools the entire space of the cabinet. |
Power control |
✔ Smooth air control (inverter-based compressor control) ✔ Fan speed control |
Temperature control on the air conditioning unit’s display |
Remote unit monitoring |
YES |
NO |
Unit placement |
Inside the cabinet on rails (7U) |
Outside on the roof or on the side of the switchboard |
Recommended placement |
For closed and open rooms ✔ Heat dissipated through the pipe to the outside of the room Ideal for smaller server rooms and office buildings |
For a ventilated room with forced air flow Heat dissipates into the room* Ideal for production halls |
* for a DX solution. In a CW solution, the heat is dissipated through a pipe to the chiller.
However, we manufacture all our technologies in the Czech Republic. This gives us hands-on control over the quality of our products.
Today, we have more than 500 employees at eight companies within the CONTEG Group.
Key technologies will be preassembled at CONTEG’s production plant. This allows us to test their functionality and compatibility in advance and significantly reduce the construction time on site.
Podívejte se, co o nás říkají klienti, pro které jsme stavěli datová centra.
A modern company praised our solution based on RF1 rack cabinets.
We delivered a rugged solution able to withstand the harsh conditions of the world-famous canal.
The Masar Project is a major undertaking in the heart of Mecca in Saudi Arabia.
CONTEG equipped ten data rooms at Noordwest Hospital in Alkmaar, the Netherlands
We built the Rondel regional data center in Ústí nad Labem, Czech Republic.
CONTEG also supplies mobile data centers for the full range of ICT performance requirements. We will install the complete mobile data center infrastructure in a steel container that can be moved anywhere.
We adhere to international quality standards for production processes, which enables us to continuously improve the quality of our products and services.
The certification proves that we really care about the environment. Our own development helps us keep improving our products and make them as environmentally friendly as possible. With our products, your data center will be labeled as eco-friendly.
Our technologies meet global quality and safety standards - we adhere to stringent regulatory and technical requirements. The certification obliges us to continuously innovate our technologies.
Demonstrates that our employees have advanced knowledge and skills in designing and implementing network structures. They will design robust network architectures for you - powerful, efficient, and energy optimized.
The enclosures of our cabinets guarantee the safety of personnel (safety standards) - especially against electric shock. They also provide robust protection for the technologies inside.
Key safety requirements for control panels - industrial panels - to meet stringent safety standards. The certification also guarantees reliability of the panels.
Contact the Sales Department or fill in the form and we will get back to you as soon as possible.